Jeremy Genter
Jeremy Genter
ZHAW
School of Engineering
Forschungsschwerpunkt Biomechanical Engineering
Technikumstrasse 71
8400 Winterthur
Work at ZHAW
Position
Research Associate / Post-Doc
Network
ORCID digital identifier
Projects
- Advancing musculoskeletal research: iterative learning control-driven system identification in a physical glenohumeral simulator for enhanced simulation, validation, and testing / Project leader / ongoing
- Development of a functional Trunk STability Test / Team member / ongoing
- InnoTreat: Towards Personalized Treatment Decisions with Digital Twins / Project leader / ongoing
- Development of trunk therapy for the assessment and training of balance & control in neurorehabilitation / Team member / ongoing
- MyoPlus: Multisegmental, Functional Muscle Simulation in Physiologic Models / Team member / completed
- TAMINA® – lmproving proximal humerus fracture treatment / Team member / completed
- Influence of additional weight carrying on load-induced changes in glenohumeral translation in patients with rotator cuff tear - a translational approach / Team member / completed
Publications
Articles in scientific journal, peer-reviewed
- Genter, J., Croci, E., Oberreiter, B., Eckers, F., Bühler, D., Gascho, D., Müller, A. M., Mündermann, A., & Baumgartner, D. (2024). The influence of rotator cuff tear type and weight bearing on shoulder biomechanics in an ex vivo simulator experiment. Journal of Biomechanics, 166(112055). https://doi.org/10.1016/j.jbiomech.2024.112055
- Genter, J., Croci, E., Müller, A. M., Mündermann, A., & Baumgartner, D. (2024). Influence of critical shoulder angle and rotator cuff tear type on load-induced glenohumeral biomechanics : a Sawbone simulator study. Applied Bionics and Biomechanics, 2024(4624007). https://doi.org/10.1155/2024/4624007
- Genter, J., Croci, E., Ewald, H., Müller, A. M., Mündermann, A., & Baumgartner, D. (2023). Ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics : a scoping review protocol. F1000Research, 11(77). https://doi.org/10.12688/f1000research.72856.3
- Genter, J., Rauter, G., Müller, A. M., Mündermann, A., & Baumgartner, D. (2023). Musculoskeletal model-based control strategy of an over-actuated glenohumeral simulator to assess joint biomechanics. At - Automatisierungstechnik, 71(7), 505–514. https://doi.org/10.1515/auto-2023-0064
- Genter, J., Croci, E., Ewald, H., Müller, A. M., Mündermann, A., & Baumgartner, D. (2023). Ex vivo experimental strategies for assessing unconstrained shoulder biomechanics : a scoping review. Medical Engineering & Physics, 117(104003). https://doi.org/10.1016/j.medengphy.2023.104003
- Croci, E., Eckers, F., Nüesch, C., Aghlmandi, S., Kovacs, B. K., Genter, J., Baumgartner, D., Müller, A. M., & Mündermann, A. (2022). Load-induced glenohumeral translation after rotator cuff tears : protocol for an in vivo study. JMIR Research Protocols, 11(12), e43769. https://doi.org/10.2196/43769
Other publications
Genter, J., Croci, E., Müller, A. M., Mündermann, A., & Baumgartner, D. (2023, September 13). Critical shoulder angle and glenohumeral biomechanics in shoulders with rotator cuff tears – an in situ study. Annual Meeting of the Swiss Society of Biomedical Engineering (SSBE), Allschwil, Switzerland, 13 September 2023.
Oral conference contributions and abstracts
- Genter, J., Croci, E., Müller, A., Mündermann, A., & Baumgartner, D. (2024, July 2). Impact of rotator cuff tears on muscle forces in weight-bearing shoulders. 29th Congress of the European Society of Biomechanics (ESB), Edinburgh, Scotland, 30 June - 3 July 2024. https://esbiomech.org/conference/archive/2024edinburgh/abstracts/974.pdf
- Genter, J., Croci, E., Müller, A. M., Mündermann, A., & Baumgartner, D. (2024, April 25). The biomechancis of shoulders with rotator cuff tears are influenced by the critical shoulder angle : an in situ simulator study. 13. Kongress Der Deutschen Gesellschaft Für Biomechanik (DGfB), Heidelberg, Deutschland, 24.-26. April 2024.
- Genter, J., Croci, E., Oberreiter, B., Eckers, F., Müller, A. M., Mündermann, A., & Baumgartner, D. (2023, July). Glenohumeral translation and muscle forces in ex vivo shoulders with rotator cuff injuries. 28th Congress of the European Society of Biomechanics, Maastricht, the Netherlands, 9-12 July 2023. https://esbiomech.org/conference/archive/2023maastricht/745.pdf
- Genter, J., Croci, E., Eckers, F., Oberreiter, B., Müller, A., Mündermann, A., & Baumgartner, D. (2023, June 29). Muskelkräfte in Schultern mit Rotatorenmanschettenrupturen während einer Abduktionsbewegung. 28. Jahreskongress der D-A-CH Vereinigung für Schulter- und Ellenbogenchirurgie, Hamburg, Deutschland, 29. Juni - 1. Juli 2023.
- Genter, J., Croci, E., Eckers, F., Oberreiter, B., Bühler, D., Mündermann, A., Baumgartner, D., & Müller, A. M. (2023, June 22). Detailed shoulder biomechanics during humeral abduction with weight-bearing : an ex vivo study using an advanced shoulder simulator. 83. Swiss Orthopaedics Annual Congress, St. Gallen, Switzerland, 21-23 June 2023.
- Genter, J., Croci, E., Eckers, F., Oberreiter, B., Müller, A. M., Mündermann, A., & Baumgartner, D. (2022, September 28). Glenohumeral contact pressure path : an ex-vivo study. 12. Kongress Der Deutschen Gesellschaft Für Biomechanik (DGfB), Köln, Deutschland, 28.-30. September 2022. https://fis.dshs-koeln.de/de/publications/abstractband-12-kongress-der-deutschen-gesellschaft-f%C3%BCr-biomechan
- Genter, J., Croci, E., Eckers, F., Oberreiter, B., Müller, A. M., Mündermann, A., & Baumgartner, D. (2022, August 17). Glenohumeral instability in rotator cuff tears : an ex-vivo study. International Shoulder Group Meeting, Delft, the Netherlands, 17-19 August 2022.
- Genter, J., Rauter, G., Rohner, M., Müller, A. M., Mündermann, A., & Baumgartner, D. (2022, June 26). Control system of a muscular controlled, experimental glenohumeral simulator. 27th Congress of the European Society of Biomechanics, Porto, Portugal, 26-29 June 2022. https://esbiomech.org/conference/archive/2022porto/papers/porto_2278.pdf
- Genter, J., Rauter, G., Rohner, M., Müller, A. M., Mündermann, A., & Baumgartner, D. (2022, June 24). A muscular controlled, ex-vivo glenohumeral simulator. 82. Swiss Orthopaedics Annual Congress, Basel, Switzerland, 22-24 June 2022.